Level gauge - pressure vessels


Level gauge, pressure vessels shall comply with the provisions of the relevantstandard, and shall meet the following requirements:
  A. Media should be based on the pressure vessel, the maximum working pressureand temperature of the correct selection;
  Two. Before installing and using low pressure vessel level gauge, hydrostatic testshould be the total nominal pressure of 1.5 times the surface; level gauge, high-pressure container with the surface meter of 1.25 times nominal pressure hydrostatic test should be carried out ;
  3. Antifrost liquid level meter should be used in pressure vessels on the mediacontaining 0 ℃;
  4. Outdoor use of the cold regions of the level gauge should be used in the folderlevel gauge of the dwelling or insulation structure;
  5 For flammable, toxic level of extreme and highly hazardous liquefied gas mediumpressure vessel plate or automatic level gauge should be used, and should preventleakage protection device;
  6. Stable liquid level indication should not float (standard) level gauge.
  More Information at Weihai Huanyu Chemical Machinery Pressure Vessel

1 条评论:

  1. In fact, the high temperature jacketed glass reactor has wide scope of application. From here: www.toption-china.com/products/glass-reactor-with-jacket-10l. Although it may be a rare word for most ordinary people, it does not influence that the glass reactors play an important role in our lives.