Common symptoms and causes of reactor
A fault phenomenon: the sealing surface leakage. Fault: screw thread loosening;sealing surface damage. Remedy: re-tighten the screw; re-grinding to polishing the sealing surface.
2, reactor failure phenomenon: the valve leak. Fault: stem (needle) valve port sealing surface damage. Exclude: maintenance, replacement of the stem (pin), the valve port.
3, reactor failure phenomenon: the outer magnet rotating within the magnet does not rotate, the motor current is reduced. Failure reasons: the reactor temperature is too high, the cooling circulation, within the magnet flux due to high temperature fade.Hydrogenation reaction, magnet sets of cracks within the magnet expansion.Remedy: notify the supplier to replace within the magnet. Failure phenomenon: themagnetic coupling actuator noise of friction. The cause of the malfunction: bushings,bearing wear, the gap is too large, rotating magnet appear beating. Remedy:Contact supplier to replace the bearings, bushings.
More Information at Weihai Huanyu Chemical Machinery Reactor
In fact, the high temperature jacketed glass reactor has wide scope of application. From here: www.toption-china.com/products/glass-reactor-with-jacket-10l. Although it may be a rare word for most ordinary people, it does not influence that the glass reactors play an important role in our lives.
回复删除