显示标签为“heat exchanger pressure”的博文。显示所有博文
显示标签为“heat exchanger pressure”的博文。显示所有博文

2011年9月2日星期五

Compressive strength of heat exchanger tube


Compressive strength of heat exchanger tube

     Foreign companies are using impregnated graphite tube, pipe specifications for? 50mm × 7mm. After the second high-temperature graphite graphite carbon tube, pipe internal heat exchanger has many small gaps, through the vacuum impregnation process, the gap was filled resin, good permeability resistance, tensile strength than the domestic high-pressure graphite tube . Because a high degree of graphite, so as the heat exchanger material, such heat exchangers have higher heat transfer coefficient, but the bending strength (vertical), the compressive strength slightly lower than the pressure-type graphite tube.

...

Details of Compressive strength of heat exchanger tube at Whreactor news center.

http://www.whreactor.com

2011年8月31日星期三

Heat Exchanger and Tube Condenser from China


Heat exchanger (tube condenser) from China

The materials of heat exchanger are carbon steel, stainless steel and the two mixing.

According to the form, our heat exchanger is classified into fixed plate type, floating head

type and U-tube heat exchanger.

According to the structure, Whreactor heat exchanger is classified into a single tube pass, dual-

pass and multi-tube pass. Heat transfer area is from 0.5 to 500 m³.

And heat exchanger is customized according to user’ needs.

Heat Exchanger and Tube Condenser from China

2011年8月25日星期四

Method of deal with heat exchanger pressure

Method of deal with  heat exchanger pressure 
    
① clear flow heat exchanger plate in the dirt or scale, the new operating system, according to the actual situation cleaned once a week. Cleaning the surface of plate scale (mainly CaCO3.), The selection of amino acid solution containing 0.3 or 0.3 Wu Luotuo with flat, 0.2 aniline, 0.1 0.8 nitric acid solution of potassium thiocyanate as a cleaning fluid, cleaning temperature 40 ~ 60 ℃ Does not remove chemical immersion cleaning equipment,heat exchangers, the heat exchanger to the cold medium into the open, export, or install equipment in the medium inlet and outlet DN25 clean install over the mouth, with a good cleaning fluid into the device, after soaking acid residue with clean water, so pH ≥ 7. Open clean when plate immersed in the cleaning solution 30 min, then brush lightly with a soft scale, and finally wash with water. Cleaning process to avoid damage to plates and rubber mats. If using non-mechanical backwash removal method, should advance in the medium inlet and outlet pipes on the road take a mouth, the car wash equipment and machinery connected to the cleaning fluid flow in the opposite direction by the media into the heat exchanger equipment, cleaning cycle time 10 ~ 15 min, flow rate controlled at 0.05 ~ 0.15 m / s. Final rinse cycle a few times, so that water quality in the Cl concentration at 25 mg / I or less.
    
② After the second best use of recycled water softening treatment, the soft water generally require the concentration of suspended solids in water less than 5 mg / L, the diameter of impurities is not greater than 3 mm, pH ≥ 7. When the water temperature is not greater than 95 ℃,, Ca, Mg concentration should not exceed 2 mol / L; when the temperature was 95C ℃ when, Ca, Mg concentration should be less than 0.3 mol / L, dissolved oxygen concentration should not at 0.1 mg / L.
    
③ For the concentrated heat exchanger heating system, water can be used once to the second method.
Heat exchanger article:  http://www.whreactor.com/